OVERVIEW
The Push-Button Wall Switch (sPODMA) Series of low voltage wall stations interface with
standard Sensor Switch occupancy sensors and power packs in order to implement a wide range
of single and bi-level switching applications. These switch devices provide an elegant and cost
effective way of deploying bi-level lighting control that meet energy and building codes without
having to source special sensors or power packs.
FEATURES
Enables Standard Occupancy Sensors to be used for Manual On Operation
Alternative Usage as Override Switch for Auto-On Applications
Single Gang Decorator Style w/ either 1 or 2 On/Off Switches
Soft-Click Push-Buttons
Programmable w/o Removing Switch Plate
Optional Dual Manual On Operation
Optional Multi-way Operation
Optional 0-10 VDC Dimming Control
Auto return to last set level - on dimmable devices, returns to last set dim level before switched off
Warranty
Five-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/support/customer-support/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application.
Specications subject to change without notice
ORDERING INFORMATION
sPODMA Example: sPODMA 347
Series Dimming # of Switches/Default on Oper. Multi-Way Color 2 Temperature / Humidity
sPODMA Wall Switch [blank] None
D 1 Dimming
Operation
[blank] 1 Switch / Auto On
SA 1 Switch/ Manual On
2P 2 Switches (Pole 1
Manual / Pole 2 Auto)
2P 2SA 2 Switches (Both Poles
Manual)
[blank] None
3X 1 Multi-Way
(e.g. 3-way)
WH White
IV Ivory
GY Gray
AL Lt. Almond
BK Black
RD Red
[blank] Standard
LT Low Temp
sPODMA D
Notes
1 Not available with 2 Pole (2P) option.
2 Matching wall plate provided for 120-277 VAC units.
Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/sensorswitch
© 2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/16/20
SPODMA
2 of 3
BLK
RED
BLUBLU
BLU
WHT
BLK/ORN
BLK
WHT
RED
WHT / BLU STRIPE
BLU / WHT STRIPE
Bi-Level Solution w/ Occupancy Sensor: 1-gang
RED
BLK
WHT
RED
BLK
N
H
sPODMA 2P
WHT
WHT
BLU
PP20 SP20
MANUAL
ON LOAD
AUTO ON
LOAD
Class 1 Connections
A1
SP20
PP20
BLK
RED
BLU
BLU
BLU
WHT
BLK/ORN
BLK
WHT
RED
WHT / BLU STRIPE
RED
WHT
WHT
WHT / BLU STRIPE
BLK
RED
BLK
WHT
RED
BLK
N
H
sPODMA
sPODMA SA
WHT
Class 1 Connections
A2
Bi-Level Solution w/ Occupancy Sensor: 2-gang
AUTO ON
LOAD
BLU
H
MANUAL
ON LOAD
WHT
WHT
WHT / BLU
BLK REDBLK RED
WHT
sPODMA SA 3X
YEL
WHT / BLU STRIPE
YEL
YEL / BLK STRIPE
YEL / BLK STRIPE
BLK
RED
BLK
RED
sPODMA SA 3X
A4
PP20
Class 1 Connections
3-Way Manual On Solution w/ Occupancy Sensor: 1-gang
BLU
BLU
WHTWHT
BLK / ORN
N
H
LOAD
WHT
BLK RED
BLK
WHT
VIO
WHT / BLU STRIPE
VIO
BLK
RED
sPODMA SA D
A4
PP20
Class 1 Connections
3-Way Manual On Solution w/ Occupancy Sensor: 1-gang
BLU
BLU
WHTWHT
BLK / ORN
N
H
0-10 VDC
BALLAST
or DRIVER
GRY
RED
If sensor also has dimming output, connect sensor VIO wire to SPODM and ballast VIO wire
BI-LEVEL (MANUAL ON / AUTO ON) SOLUTION w/ OCCUPANCY SENSOR: 1 GANG
Bi-level (auto-on / manual on) solution w/
occupancy sensor: 2 gang
Note: If sensor also has dimming output (e.g., CM 9 ADC), connect sensor VIO wire
to SPODMA and ballast/driver VIO wire. Lowest output level always takes
precedence. If no sensor is used, connect the SPODMA white wire to the red wires.
3-WAY MANUAL ON SOLUTION w/ OCCUPANCY SENSOR
MANUAL ON w/ DIMMING & OCCUPANCY SENSOR
Note 1: SPODMA (SA) 3X D units should only be used in multi-way applications with SPODMA
(SA) 3X units (non-dimming) as dimming levels are not communicated between devices.
Note 2:
manner as bottom right SPODMA SA 3X unit in diagram above.
Note 3: If no sensor is used, connect the SPODMA white wire to the red wires.
TYPICAL CONFIGURATIONS
PROGRAMMING INSTRUCTIONS (Please read all 7 steps before programming)
(NOTE: 18 AWG wire is recommended for all wiring)
1. Enter programming mode by pressing & holding upper most button until LED flashes rapidly. Release button.
2. Enter the On Mode function by pressing button twice.
3. The current On Mode setting will then be fed out in a sequence of LED flashes as indicated in the table below (e.g., one flash for Auto-On). To change the setting, proceed to
step 4 before sequence repeats 10 times.
4. At any time while the switch is flashing back the current On Mode setting, interrupt it by pressing button the number of times for the new desired On Mode setting as
indicated in the table below (e.g., press twice for Manual On). Switch will begin to flash back new setting as confirmation.
5. Next, while the switch is flashing back new setting, interrupt it by pressing and holding button until LED flashes rapidly. Release button.
6. As final confirmation and activation of the new setting, press button two times.
7. LED will flash twice indicating acceptance of new setting. If two flashes are not seen, repeat 7 step process.
Note: To exit programming mode without saving, wait for blink back sequence to repeat 10 times then return to step 1.
Function Number Function Name Settings (see ordering block for defaults)
Setting Number Pole 1 Pole 2 (2P devices only)
2On Mode
1Auto-On Manual On
2Manual On Auto-On
3 (2P devices only) Manual On Manual On
4 (2P devices only) Auto-On Auto-On
Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/sensorswitch
© 2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/16/20
SPODMA
3 of 3
SPECIFICATIONS
Electrical Input Ratings 12-24VAC/VDC, 5mA
Output Ratings Sinks <20mA
- 800 W @ 120VAC
- 1200 W @ 277VAC
Mechanical Dimensions 2.74”H x 1.68”W x 1.63”D (70mm x 43mm x 41mm) - does not include ground strap
Mounting Single-Gang Box or Low Voltage Ring
Connection Type Low Voltage Leads
Environmental Warrantied Operating Temperature -22°F to 185°F (-30°C to 85°C)
Relative Humidity Up to 90%, Non-Condensing
Standards/ Ratings RoHS
General Standards/ Ratings CEC Title 20