Lux Products 3M-22 Instrukcja obsługi

Kategoria
Termostaty
Typ
Instrukcja obsługi
Your thermostat is a precise instrument, handle it with care.
Turn off electricity to the appliance before installing or
servicing thermostat or any part of the system.
Do not turn electricity back on until work is completed.
Do not short (jumper) across electric terminals at control on
furnace or air conditioner to test the system. This will damage
the thermostat and void your warranty.
All wiring must conform to local codes and ordinances.
This thermostat is designed for use with 24 volt AC and
millivolt systems. The thermostat should be limited to a
maximum of 1.0 amps; higher amperage may cause damage
to the thermostat.
Caution
Install guide 3M-22
ENGLISH
Location
Caution
Tools
To avoid electrical shock and to prevent damage to the furnace, air conditioner,
and thermostat, disconnect the power supply before beginning work.
This can be done at the circuit breaker, or at the appliance.
Replacement installations -
mount the new thermostat in place of the old one.
New installations -
follow the guidelines listed below.
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and
in a room that is used often.
Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator register, or fireplace; near hot
water pipes in a wall; near a stove on the other side of a wall.
Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
Do not locate in a damp area. This can
lead to corrosion that will shorten thermostat
life.
Do not locate where air circulation is poor,
such as: in a corner or an alcove; or behind
an open door.
Do not install the unit until all construction
work and painting has been completed.
This thermostat does not require leveling.
You will need a small Phillips screwdriver and possibly a drill
with 3/16-in. (4.8mm) bit for wall mounting.
Good
5ft.
(1.5m)
PG
1
PG
2
Install guide 3M-22
Remove old unit
Prepare wires
IMPORTANT : LABEL ALL WIRES
BEFORE DISCONNECTING THEM!
Switch electricity to the furnace and
air conditioner OFF; then proceed with the
following steps.
Remove cover from old thermostat. Most are
snap-on types and simply pull off. Some have
locking screws on the side or front. These must
be loosened. Note the letters printed near the terminals. Attach
labels (enclosed) to each wire for identification.
Label the wires one at a time. You must label all the wires before
you proceed. With all wires labeled, remove them from the old unit.
Make sure the wires do not fall back inside the wall. You can wind
them around a pencil to keep them from falling.
Loosen all screws on the old thermostat and remove it from the wall.
Fill wall opening with non-combustible insulation to prevent drafts.
PG
3
PG
4
Caution
Read instructions carefully before removing any wiring from existing thermostat.
Wires must be labeled before they are removed. THERE IS NO STANDARD
COLOR CODE. When removing wires from their terminals, ignore the color of
the wires since these may not comply with any standard.
You will need at least 2.6" of wire for each
of your connections to the 3M-22.
If you do not have enough wire, splice
additional wire to allow enough slack.
Fan out wires below the hole as shown.
W
Trim
2.6"
Before you Connect Wires
Caution
Do not allow wires to touch each other or parts on thermostat.
Please follow these guidelines for safe and secure
wire connections.
Easy Terminals do not require stripping the wire.
Clip any bare wire from previous installation.
• Take care not to damage the labels for each wire in handling.
Fan wires out as illustrated with 3M-22 below the wall opening.
• Wires will dress behind the 3M-22 and up over the terminal area.
Use the Step-By-Step diagram as your guide.
Do not bunch wires behind 3M-22. Feed slack back into the wall
opening.
Insert the wire in the terminal and tighten
the screw securely.
You will need to set Configuration
Jumpers per the Step-By-Step
diagram. A needle-nose plier may be
required to modify jumper positions
PG
5
PG
6
Determine which step-by-step wiring
diagram below you should use. Make
sure your wires are labeled. This may
require you to find the 'other end' connection for each wire on your heating or
air conditioning equipment and read the label there.
If you have a wire marked "C" it is optional. If you do connect it, the
thermostat will draw power from the C wire. This extends battery life.
What wires do you have?
Jumpers
W
If you combination of wires is not above you can use the
wiring table on pages 24-25 to determine your connections,
or call our USA support line at 1-888-607-5824 for help.
Find the referenece page with your wiring
diagram and jumper set-up information.
Remember, the
C
wire is optional.
Find the set-up diagram for your system
PG
7
PG
8
Go To Page 18Go To Page 17Go To Page 16
Go To Page 21Go To Page 19
C W2 W Y Y2 RH G
2 stage Cool
2 stage Heat
W
2
C W Y RH RC G
5 Wire
Heat/Cool
W
C W Y RH G
4 Wire
Heat/Cool
W
C W RH G
3 Wire
Heat
W
C W RH
2 Wire
Heat
W RH A
3 Wire
Zoned
Hot Water
Go To Page 20
C B or O W2 Y RH G
5 Wire
Heat Pump
w/ Aux Heat
B
C B or O Y RH G
4 Wire Heat Pump
w/o Aux Heat
B
Go To Page 15
Go
To
PAGE 22
PG
9
PG
10
Install AAA Batteries
The 3M-22 requires 2 AAA batteries to operate .
Switch MODE switch to OFF and the FAN switch to AUTO.
Install 2 AAA alkaline batteries according to the polarity noted in
the compartment. LCD segments will go on.
Press the RESET button (under top cover) to clear transient
program memory. NOTE: Replace the batteries when this LOW
battery indicator appears on the display or once a year.
Replace top and bottom covers on unit.
Wall
Wires
3M-22
Wall anchor
Hold the 3M-22 against the wall, with the wires coming
over the top above terminal block. The 3M-22 will cover the
hole in the wall.
Position 3M-22 for best appearance. Use the optional stand-
offs if more space for wires is needed behind the 3M-22.
Attach the base to the wall with the screws provided.
If you are mounting the base to sheet rock or if you are using
the old mounting holes, use the plastic anchors provided. Drill
a 3/16-in.(4.8mm) hole for the insert at
each screw location, then mount the base.
Mount the 3M-22
AAA
+
-
AAA
+
-
W
W
NOTE: If you have labeled your wires, follow the correct Step-By-Step, and
these Check procedures do not operate your system call support at
1-888-607-5824
Check Unit
Follow these procedures to verify you
have correctly installed the 3M-22.
To check Fan: (If you connected the
G wire - fan relay)
Switch the FAN switch to the ON
position. Verify that air is blowing from
the system. Return to AUTO position
for normal operation.
To check HEAT mode:
Set the mode switch to HEAT.
Set the fan switch to AUTO.
Using the TEMP + button raise the Target Temp to 90deg.
Allow the system 2 min to respond.
Verify that heat is blowing from the system.
To check COOL mode:
Set the mode switch to COOL.
Press the TEMP - button to a temp 5 degrees below the room temp.
Allow the system 2 minutes to respond.
Verify that cool air is blowing from the system.
Congratulations, you have successfully installed your unit.
Please proceed to the OPERATING Guide to initialize the 3M-22.
PG
11
PG
12
TEMP
UP button
TEMP
DOWN button
Temperature
Display
Mode
Switch
Fan
Switch
BATTERIES ONLY - This thermostat can run on batteries only using 2AAA
alkaline batteries. The batteries will last at least 1 year; replace the batteries
once a year or when the low battery icon comes on the display. If the batteries
are not replaced, the thermostat will shut off the HVAC and then stop working.
24VAC - This thermostat can run on the HVAC 24VAC (C wire) if available.
As shown in the wiring diagrams, the C wire is the other side of the 24VAC
heating transformer and can be found where the other thermostat wires
connect at the wall or at the furnace. Do not use the common or ground side
of the line voltage. If the C wire is used, the batteries are then for back-up in
case of power loss only and will last much longer. With the C wire connected,
the thermostat will continue to work if the batteries die or are removed.
Power Options
PG
14
PG
13
NOTE:Your thermostat comes from the factory calibrated to +/- 1
o
of actual
temperature. It is an accurate instrument. If you want your thermostat to
display the same temperature as another thermometer in your home, you
can adjust its calibration.
To change the calibration:
Set the Mode switch to HEAT or COOL.
Locate the TIME SET button and press it. The
current calibration factor (+/-) of the 3M-22 will appear
in the LCD display as well as the modified temp.
Push the UP or DOWN arrows until the desired
calibration factor is reached.
Press HOME to save. The new calibrated temperature
will be displayed on the LCD.
Calibration
Calibrate button
PG
15
2 WIRE HEAT Heating GAS MILLIVOLT or 24vac
NOTE: Wires marked with
dotted line are optional.
PG
16
3 Wire Heat
3M-22
W
R
C
GAS Milivolt Heat
C B O W
2
W
Y Y
2
RH RC G A
3M-22
W
R G
C
HVAC SYSTEM
C B O W
2
W
Y Y
2
RH RC G A
STEP 1 - Connect the R (or RH) wire to the RH terminal on
the 3M-22. This connects the Heater Power to the thermostat.
STEP 2 - Connect the W wire to the W on the 3M-22.
This connects the heater control line to the 3M-22.
STEP 3 - Set Config jumpers per this diagram.
Your Heater is now connected to the 3M-22.
Please Go To Page 9
STEP 1 - Connect the R (or RH) wire to the RH terminal
on the 3M-22. This connects to the Heater Power .
STEP 2 - Connect the W wire to the W terminal on the
3M-22. This connects the heater control line to the
3M-22.
STEP 3 - Connect the G wire to the G terminal on the
thermostat. This connects the Fan to the 3M-22
STEP 4 - Set Config jumpers per this diagram. If you
have Electric heat set 5, if you have Gas or Oil set 7.
Your system is now connected to the 3M-22.
Please Go To Page 9
OPTIONAL POWER
OPTIONAL POWER
SET JUMPERS
SET JUMPERS
or
1 2 3
4
6
8
5
7
1 2 3
4
6
8
5
7
STEP 1 -
Connect the
W
wire to the
W
terminal on the
thermostat. This connects to the heater control line.
STEP 2 -
Connect the
Y
wire to the
Y
terminal on the
3M-22. This connects to the Cooler compressor.
STEP 3 -
Connect the
RH
wire to the
RH
terminal and the
RC
wire to the
RC
terminal on the 3M-22. This connects
the Heater and Cooler Power.
STEP 4 -
Connect the
G
wire to the
G
terminal on the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
have Electric heat set 5, if you have Gas or Oil set 7.
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
STEP 1 -
Connect the
W
wire to the
W
terminal on the
thermostat. This connects to the heater control line.
STEP 2 -
Connect the
Y
wire to the
Y
terminal on the
3M-22. This connects to the Cooler compressor.
STEP 3 -
Connect the
RH
or
R
wire to the
RH
terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 -
Connect the
G
wire to the
G
terminal on the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
have Electric heat set 5, if you have Gas or Oil set 7.
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
W Y RH G
PG
17
4 Wire Heat/Cool
3M-22
Terminals
Y
W
R G
C
HVAC SYSTEM
C B O W
2
W
Y Y
2
RH RC G A
OPTIONAL POWER
W Y RH RC G
PG
18
5 Wire Heat/Cool
3M-22
Terminals
YW
RH RC
G
C
HVAC SYSTEM
C B O W
2
W
Y Y
2
RH RC G A
OPTIONAL
or
1 2 3
4
6
8
5
7
SET JUMPERS
SET JUMPERS
or
1 2 3
4
6
8
5
7
STEP 1 - Connect O wire to the O terminal or B wire to the B terminal on
the 3M-22. (If you have both O and B - connect O wire to O terminal
DO NOT connect B to B terminal - see pg 24 Trane for B wire terminal)
This connects the change-over valve.
STEP 2 - Connect the Y wire to Y on the 3M-22.
This connects the Compressor.
STEP 3 - Connect the R wire to RH on the 3M-22.
This connects to the 24vac power.
STEP 4 - Connect the G wire to the G terminal on the
3M-22. This connects the Fan.
STEP 5 - Set Config jumpers per this diagram.
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
B
or
O Y R G
PG
19
PG
20
4 Wire Heat Pump w/o Aux
OPTIONAL POWER
STEP 1 - Connect O wire to the O terminal or B wire to the B terminal on
the 3M-22. (If you have both O and B -connect O wire to O terminal DO
NOT connect B to B terminal - see pg 24 Trane for B wire terminal)
STEP 2 - Connect the W2 wire to W2 on the 3M-22.
STEP 3 - Connect the Y wire to Y on the 3M-22.
STEP 4 - Connect the R wire to RH on the 3M-22.
STEP 5 - Connect the G wire to G on the 3M-22.
STEP 6 - Set Config jumpers per this diagram.
Set jumper 1 if you have Gas or Oil aux heat.
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
B
or
O W2 Y RH G
5 Wire Heat Pump w/ Aux Heat
3M-22
Terminals
YB
R G
C
HEAT PUMP SYSTEM
O
C B O W
2
W
Y Y
2
RH RC G A
SET JUMPERS
or
or
SET JUMPERS
3M-22
Terminals
Y
W2
B
R G
C
HEAT PUMP SYSTEM
O
C B O W
2
W
Y Y
2
RH RC G A
OPTIONAL POWER
or
or
1 2 3
4
6
8
5
7
1 2 3
4
6
8
5
7
?
W
R A
Motor Valve
C B O W
2
W
Y Y
2
RH RC G A
PG
22
W RH [A?] 3 Zoned Hot Water - Motor Valve
Step 1 - based on your valve type
Motor driven Valve- Connect the R (or RH) wire to the RH
terminal on the 3M-22. Connect the W wire to the W terminal
on the 3M-22. Connect the remaining wire to the A terminal.
Solenoid valve -Connect the R (or RH) wire to the RH
terminal on the 3M-22. Connect the W wire to the A terminal
on the 3M-22. Connect the remaining wire to the W
terminal.
STEP 2 - Set Config jumpers per this diagram.
Your system is now connected to the 3M-22.
Please Go To Page 9
STEP 1 -
Connect the
W
wire to the
W
terminal and
W2
to
W2 on the 3M-22. This connects 2 stages of heat.
STEP 2 -
Connect the
Y
wire to the
Y
terminal and Y2 wire
to Y2 on the 3M-22. This connects 2 stages of cool.
STEP 3 -
Connect the
RH
or
R
wire to the
RH
terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 -
Connect the
G
wire to the
G
terminal on the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
have Electric heat set 5, if you have Gas or Oil set 7.
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
W2 W Y Y2 RH RC G
PG
21
2 Stage Heat and Cool
3M-22
Terminals
3M-22
Terminals
Y2
W2
W Y
RH
RC
G
C
HVAC SYSTEM
C B O W
2
W
Y Y
2
RH RC G A
OPTIONAL
POWER
SET JUMPERS
or
1 2 3
4
6
8
5
7
SET JUMPERS
1 2 3
4
6
8
5
7
This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It
cannot be used with line voltage systems. This thermostat is digital and your desired heat or
cool temperatures can easily be set on the large screen with the +/- buttons on the front. A
minimum 4 minute off time protects heating and cooling systems from damage.
This thermostat uses a new technique called sequential staging for more comfort with
faster reaction to requested temperature changes. When using a heat pump with Aux heat, if
the heat pump cannot keep up and/or is
defective, remove jumper from position 8 and put
jumper on position 6 and the Aux heat will then
be your only source of heat. Be sure to restore it
to PUMP when the pump is again operational as
aux heat is more expensive than pump heat.
3M-22 Features
Wire Reference
Your Wires
Filtrete Terminal
R or V or VR RH and RC Single power for HEAT and COOL
RH or 4 RH Power for HEAT (RH not connected to RC)
RC RC Power for COOL (RH not connected to RC)
W W Heat control
W2 W2 2nd stage HEAT or heat pump auxiliary heat
? A 3rd wire for zoned hot water heat (see zoned)
Y Y COOL control
Y2 Y2 2nd stage COOL control
G or F G FAN control
C or X C Common 24VAC power (to power thermostat)
E Emergency heat (do not connect, tape off)
L System monitor (do not connect, tape off)
T Outdoor sensor (do not connect, tape off)
B or B Heat pump changeover (cool to heat, powered in heat)
O O Heat pump changeover (heat to cool, powered in cool)
B and O
SEE NOTE
PG
23
PG
24
B and O
NOTE: If
there are both
B and O wires
(Trane pump
products)
DO NOT
CONNECT B
to B terminal,
connect B to C
terminal
1002-005
Customer Support: 888-607-5824 or
Visit our website www.radiothermostat.com/filtrete
Printed in China
Wire Reference cont
Your Wires
Filtrete Terminal
Lennox Heat Pump
V or VR or R RH
M or Y Y
Y or W or W2 W2
F or G G
R or O O
X or X2 or C C
Trane Products [American Standard]
B C
W or W1 W2
Zoned Systems
Your Wires
Filtrete Terminal
2 wire Zoned Hot Water
R RH
W W
3 Wire Zoned Hot Water
Motor Driven Valves
R RH
W W
Y (the 3rd wire) A
3 Wire Zoned Hot Water
Solenoid Valves
R RH
W A
Y (the 3rd wire) W
PUMP AUX
ELECT
CELSIUS
321
6
8
OPEN
PUMP AUX
GAS OR OIL
FAHRENHEIT
CLOSED
CELSIUS
TYPE
AUX
FAHRENHEIT
HEAT
PUMP
HEAT PUMP'S
AUX ONLY
12 hr
24hr
12hr clock
24hr clock
CLOSED
CLOSED
OPEN
OPEN
SINGLE
POWER(R)
RESET UNIT
GAS/ELEC HEAT
OPEN
4
5
7
POWER RH
POWER RC
AFTER CHANGING JUMPERS
GAS OR OIL
ELECTRIC
CLOSED
HEAT
OR PUMP
CLOSED
CLOSED
HVAC
POWER
OR
SELECT
PG
25
PG
26
Jumper Reference
Configuration jumpers allow your
3M-22 to be adapted to many
different HVAC control applications.
NORM/PUMP/AUX
SELECT
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Lux Products 3M-22 Instrukcja obsługi

Kategoria
Termostaty
Typ
Instrukcja obsługi

w innych językach