Aero Pure 00853578008424 Specyfikacja

Typ
Specyfikacja

Niniejsza instrukcja jest również odpowiednia dla

Model: ABF 110DH G6 Series
4” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
112
95.6
Noise (sones)
1.0
1.2
Power Consumption (Watts)
16
17.5
Energy Efficiency (CFM/Watts)
7.0
5.5
Speed (RPM)
1159
N/A
ENERGY STAR rated
Yes
Grille Dimensions
13” x 13”
Model
Qty
Comments
Specifications
ABF 110DH G6 Series
Quiet Bathroom Ventilation Fan with
Adjustable Speed and Humidity Sensor
ETL/cETL Listed for installation over tub/shower enclosure
when used with GFCI circuit wiring
Description: Quiet DC (Direct Current) bathroom fan with adjustable
speed control (50-80-110 CFM) engineered for continuous run User
adjustable Humidity Sensor Ceiling mount Suitable for new
construction or remodeling HVI certified ENERGY STAR certified
ETL/cETL listed for use in insulated ceilings (Type I.C.).
Motor/Blower: Brushless high performance DC motor engineered for
continuous energy efficient operation; power rating 120v/60Hz; motor
equipped with thermal shut off.
Housing: Galvanized steel body; duct connector adapts to 4”, 5” or 6”,
built-in back draft dampener; patented quick mounting anti-vibration
bracket included; designed for installation in ceilings with minimum of
8” clearance.
Grille: Low maintenance, wipe clean; attaches to housing with torsion
springs.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze (OR).
Ventilating Area: For bathrooms up to 110 sq ft.
Installation: Must be installed by licensed professional. Complete
installation instructions included.
Warranty: 6 Years
Architect’s Specifications: Ventilation fan will be ceiling mount,
ENERGY STAR qualified, adjustable speed of 50-80-110 CFM, with no
less than 110 CFM and no more than 1.0 Sones as certified by HVI at
0.1 static pressure in inches water gauge. Power consumption shall be no
greater than 16.0 watts and ENERGY STAR rated with an efficiency
rating of no less than 7.0 CFM/watt. The motor will be enclosed brushes
DC motor engineered for continuous operation. CFM switch tab will
allow for 3 separate airflow (CFM) settings for 4”, 5”, or 6” duct. Fan
will begin operation when humidity rises above user adjusted setpoint.
Adjustable timer. Fan shall be listed for tub/shower enclosure when used
with GFCI branch circuit wiring and shall be ETL/cETL listed for use
in insulated ceiling (Type I.C.). Fan shall be ASHRAE 62.2, LEED,
California Title 24, and Washington VIAQ compliant.
Aero Pure, LLC 1006 Bankton Circle Ste B Hanahan, SC 29410 843.377.8642
www.aeropurefans.com