Novus NVIP-2VE-6402M (NVIP-2DN3034AV/IR-1P) Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi
User s ma n ual
(shor t for m )
NVIP-2VE-6402M
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
2
IMPORTANT SAFEGUARDS AND WARNINGS
EMC (2014/30/UE) and LVD (2014/35/UE) Directives
CE Marking
Our products are manufactured to comply with the requirements of the following directives and
national regulations implementing the directives:
- Electromagnetic compatibility EMC 2014/30/UE.
- Low voltage LVD 2014/35/EC with further amendment. The Directive applies to electrical
equipment designed for use with a voltage rating of between 50VAC and 1000VAC as well as
75VDC and 1500VDC.
WEEE Directive 2012/19/UE
Information on Disposal for Users of Waste Electrical and Electronic Equipment
This appliance is marked according to the European Directive on Waste Electrical and Electronic
Equipment (2012/19/UE) and further amendments. By ensuring this product is disposed of correctly,
you will help to prevent potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product, or the documents accompanying the product, indicates that this appliance
may not be treated as household waste. It shall be handed over to the applicable collection point for
used up electrical and electronic equipment for recycling purpose. For more information about
recycling of this product, please contact your local authorities, your household waste disposal service
or the shop where you purchased the product.
RoHS Directive 2011/65/UE
Information concerning the restriction of use of hazardous substances in electrical electronic
equipment.
Out of concern for human health protection and friendly environment, we assure that our products
falling under RoHS Directive regulations, regarding the restriction of the use of hazardous substances
in electrical and electronic equipment, have been designed and manufactured in compliance with the
above mentioned regulations. Simultaneously, we claim that our products have been tested and do not
contain hazardous substances whose exceeding limits could have negative impact on human health or
natural environment.
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed
for self installation in households by individuals without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other devices:
The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other
devices during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN
PRODUCT IN USERS MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE
PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE
PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING
THE MANUFACTURERS RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION.
EMC (2014/30/UE) and LVD (2014/35/UE) Directives
CE Marking
Our products are manufactured to comply with the requirements of the following directives
and national regulations implementing the directives:
- Electromagnetic compatibility EMC 2014/30/UE.
- Low voltage LVD 2014/35/EC with further amendment. The Directive applies to
electrical equipment designed for use with a voltage rating of between 50VAC and 1000VAC as
well as 75VDC and 1500VDC.
WEEE Directive 2012/19/UE
Information on Disposal for Users of Waste Electrical and Electronic Equipment
This appliance is marked according to the European Directive on Waste Electrical and
Electronic Equipment (2012/19/UE) and further amendments. By ensuring this product is
disposed of correctly, you will help to prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate waste
handling of this product.
The symbol on the product, or the documents accompanying the product, indicates that this appliance
may not be treated as household waste. It shall be handed over to the applicable collection point for
used up electrical and electronic equipment for recycling purpose. For more information about
recycling of this product, please contact your local authorities, your household waste disposal service
or the shop where you purchased the product.
RoHS Directive 2011/65/UE
Information concerning the restriction of use of hazardous substances in electrical electronic
equipment.
Out of concern for human health protection and friendly environment, we assure that our
products falling under RoHS Directive regulations, regarding the restriction of the use of
hazardous substances in electrical and electronic equipment, have been designed and
manufactured in compliance with the above mentioned regulations. Simultaneously, we
claim that our products have been tested and do not contain hazardous substances whose exceeding
limits could have negative impact on human health or natural environment.
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed
for self installation in households by individuals without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other devices:
The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other
devices during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN
PRODUCT IN USERS MANUAL AND OTHER DOCUMENTS DELIVERED WITH
THE PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF
THE PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR
OF EXCLUDING THE MANUFACTURERS RESPONSIBILITY FOR THE RESULTS
OF SUCH AN ACTION.
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
3
IMPORTANT SAFEGUARDS AND WARNINGS
WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER DEVICE
OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE MANUAL
PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER-
SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY OPEN
THE UNIT.
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE PERSONNEL
AND SHOULD CONFORM TO ALL LOCAL REGULATIONS.
IMPORTANT SAFEGUARDS AND WARNINGS
1. Prior to undertaking any action please consult the following manual and read all the safety and operating
instructions before starting the device.
2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is
necessary;
3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct
influence on users safety and durability and reliability of the device;
4. All actions conducted by the servicemen and users must be accomplished in accordance with the users
manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
7. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not
recommended since it may lead to heat build-up and damaging the device itself as a consequence;
8. Mounting the camera on unstable surface or using not recommended mounts is forbidden. Improperly
mounted camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted
by qualified personnel with proper authorization, in accordance with this users manual.
9. Device should be supplied only from a power sources whose parameters are in accordance with those
specified by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera
from a power sources with unknown parameters, unstable or not meeting producers requirements;
10. Signal cables (conducting TV or / and telemetric signal) should be placed in a way excluding the possibility
of damaging them by accident. Special attention must be paid to cables getting from the camera and
connecting the power supply;
11. To avoid equipment damage, whole TV circuit should be equipped with properly made discharge-, overload-
and lightning protection devices. Usage of separating transformers is advised;
12. Electric installation supplying the device should be designed to meet the specifications given by the producer
in such a way that overloading is impossible;
13. User cannot repair or upgrade the equipment himself. All maintenance actions and repairs should be
conducted only by qualified service personnel;
14. Unplug the camera from the power source immediately and contact the proper maintenance
department when the following occurs:
Damages to the power cord or to the plug itself;
Liquids getting inside the device or exposure to strong mechanical shock;
Device behaves in a way not described in the manual and all adjustments approved by the
manufacturer and possible to apply by user himself, seem not to have any effect;
Camera or its casing is damaged;
Atypical behaviour of the camera components can be seen (heard).
15. In necessity of repairs attention to using only original replacement parts (with their parameters
in accordance with those specified by the producer) should be paid. Non-licensed service and non
-genuine replacement parts may cause fire or electrocution.
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
4
TABLE OF CONTENTS ..................................................................................................... 4
1. FOREWORD INFORMATION ................................................................................... ..5
1.1. General characteristics ......................................................................................... 5
1.2. Technical specification .................................................................................... ...6
1.3. Camera dimension ........................................................................................... ...7
1.4. Package contents ............................................................................................... ...7
2. START-UP AND INITIAL IP CAMERA CONFIGURATION ................................. 8
2.1. Description of connectors and control tools ........................................................ 8
2.2. Connecting ethernet cable .................................................................................. 9
2.3. Connecting power supply to the camera ............................................................. 9
2.4. Installation ......................................................................................................... 10
2.5. Starting the IP camera ........................................................................................ 11
2.6. Initial configuration via the web browser .......................................................... 12
2.7. Security recommendations for network ............................................................ 13
3. NETWORK CONNECTION USING WEB BROSWER ......................................... 14
3.1. Recommended PC specification for web browser ............................................. 14
3.2. Connection with IP camera via web browser ..................................................... 14
4. WWW INTERFACE -USING AND CONFIGURING .............................................. 16
4.1. The Remote Preview interface .......................................................................... 16
4.2. Lens control. ....................................................................................................... 17
5. CONNECTING ACCESORIES ................................................................................. 17
5.1. Connecting audio input. .................................................................................... 17
6. RESTORING FACTORY DEFAULTS ..................................................................... 17
6.1. Restoring factory defaults by software (web browser level) .............................. 18
6.2. Restoring factory defaults by software (NMSiptool level) ............................... 18
TABLE OF CONTENTS
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
5
1. FOREWORD INFORMATION
1.1. General Characteristics
Imager resolution: 2.0 megapixels
Mechanical IR cut filter, IR operation capability
Min. Illumination from 0 lx with IR LED on
Wide Dynamic Range (WDR) for enhanced image quality in diverse light conditions
Digital Noise Reduction (DNR)
Lens type: motor-zoom, f= 2.8-12mm/F=1.4
Built-in LED illuminator: 2 pcs LED
Compression: H.264, H2.65/ MJPEG
Max video processing resolution: 1920 x 1080
Multi streaming: compression, resolution, speed and quality defined individually for each video
stream
ROI functions
Motion detection
Private Zones
RTSP protocol support for video transmission
Schedule functions
Audio input
BNC output
Built-in webserver: camera configuration through the website
Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server
Software: NMS (NOVUS MANAGEMENT SYSTEM) for video recording, live monitoring,
playback and remote IP devices administration
Video Content Analysis (VCA):
Exception
Line Crossing
Intrusion
Power supply: 12VDC, PoE (Power over Ethernet)
Information
Depending on the type of recorder/registration system, the range of features and options may vary. Full
list of camera functionality available from a given type of recorder is included in the instruction manual
on www.novuscctv.com/en
Information!
The manufacturer reserves the right to printing errors and technical specifications changes
without prior notice.
FOREWORD INFORMATION
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
6
1.3. Technical specification
FOREWORD INFORMATION
Image
Image Sensor 2 MPX CMOS sensor 1/2.7” APTINA
Number of Effective Pixels 1920 (H) x 1080 (V)
Min. Illumination
0.07 lx/F1.4 - color mode ,
0 lx (IR on) - B/W mode
Electronic Shutter auto: 1/25 s ~ 1/100000 s
Wide Dynamic Range (WDR) yes
Digital Noise Reduction (DNR) 3D
Defog Function (F-DNR) yes
Lens
Lens Type motor-zoom, f=2.8 ~ 12 mm/F1.4
Day/Night
Switching Type mechanical IR cut filter
Switching Mode auto, manual, time
Switching Level Adjustment yes
Switching Schedule yes
Visible Light Sensor yes
Network
Stream Resolution 1920 x 1080 (Full HD), 1280 x 720 (HD), 640 x 480 (VGA), 320 x 240 (QVGA)
Frame Rate 30 fps for 1920 x 1080 (Full HD) and lower resolutions
Multistreaming Mode 3 streams
Video/Audio Compression H.264+, H.265, MJPEG/G.711
Number of Simultaneous Connections max. 4
Bandwidth 9 Mb/s in total
Network Protocols Support TCP/IP, UDP, FTP, DHCP, DDNS, NTP, RTSP, UPnP, PPPoE, SMTP
ONVIF Protocol Support Profile S (ONVIF 2.3)
Camera Configuration
from Internet Explorer
languages: Polish, English, Russian, and others
Compatible Software NMS
Other functions
Privacy Zones 4
Motion Detection yes
Region of interest (ROI) 8
Video Content Analysis (VCA)
Exception, Line Crossing, Intrusion
Image Processing 90˚ image rotation, 180˚ image rotation, sharpening, mirror effect
Prealarm/Postalarm -/up to 120 s
System Reaction to Alarm Events e-mail with attachment, saving file on FTP server
IR LED
LED Number 2
Range 30 m
Angle 90°
Interfaces
Video Output BNC, 1.0 Vp-p, 75 Ohm
Audio Input/Output 1 x Jack (3.5 mm)/-
Network Interface 1 x Ethernet - RJ-45 interface, 10/100 Mbit/s
Installation parameters
Dimensions (mm) 130 (Ф) x 119 (H)
Weight 0.7 kg
Degree of Protection IP 66 (details in the further part of the manual)
Enclosure vandal proof aluminium, white
Power Supply PoE, 12 VDC
Power Consumption 3 W , 5.5 W (IR on)
Operating Temperature -20°C ~ 50°C
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
7
FOREWORD INFORMATION
1.4. Camera dimensions (in millimeters)
1.5. Package contents
After opening the package make sure that the following elements are inside:
IP camera
Accessories bag
Short version of users manual
If any of this elements has been damaged during transport, pack all the elements back into the
original box and contact your supplier for further assistance.
CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches
the temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
CAUTION!
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
8
START-UP AND INITIAL IP CAMERA CONFIGURATION
2. START-UP AND INITIAL IP CAMERA CONFIGURATION
2.1 View of the camera, layout of the camera items
1. BNC output (Analog)
2. Audio input (MIC)
3. Power supply 12VDC
4. 100 Mb/s Ethernet port (RJ-45 hermetic connector)
1. Screws locking camera base
2. IR LED
3. Light Sensor
1
2
3
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
9
2.2. Connecting ethernet cable
To maintain tightness of ethernet cable connection, please follow instruction below:
1. Loosen the nut (a) from the main element (b).
2. Run power cable (without RJ-45 connector) though both elements. Then crimp the cable with RJ-45
connector.
3. Connect the cable to the hermetic connector (c), screw main cover (b), then screw the nut (a).
WARNING! 12VDC power connector and others are not hermetic. User should seal power connector
by himself.
2.3. Connecting power supply to the camera.
Camera can be supplied using external power supply unit corresponding with the camera parameters or
by using RJ45 network socket and PoE (802.3at Type 1 ) power supply unit.
Information:
Power supply adapter is not included. Please use power adapter with parameters specified in users
manual.
CAUTION:
Do not use power supplies and POE adapters not compatible with IEEE 802.3af standard!
Damage resulting from the use of improper power supply is not covered under warranty!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
START-UP AND INITIAL IP CAMERA CONFIGURATION
a
b
a
b
c
12 VDC +
GND
Camera 12 VDC power supply
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
10
2.4. Installation
1. Remove locking screws from camera base and then remove camera base.
2. Use the included mounting template or the camera base plate to mark holes for mounting
screws.
3. Drill mounting and cable holes in previously selected points.
4. Mount the camera base using screws on smooth surface providing declared degree of IP protec-
tion.
5. Mount camera to camera base and screw locking screw.
6. Adjust the position of the camera module. If required, loosen the screws blocking camera
module.
CAUTION!
The declared degree of protection of the camera relates to its housing and does not take
into account the possibility of moisture infiltration into the interior of the camera by
connecting cables. Connection cables protection through i.e. sealing up is the responsibil-
ity of the camera installer. The manufacturer is not liable for any damages to the camera
caused as a result of failing in performing that activity by installer, which also means
that camera damaged in that way is not subject to warranty repairs
START-UP AND INITIAL CAMERA CONFIGURATION
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
11
2.5. Starting the IP camera
To run NOVUS IP camera you have to connect ethernet cable between camera and network switch.
To power it up you can connect it directly via power supply adapter with parameters compatible with
camera power supply specification, or camera can be powered with PoE (IEEE 802.3af ) compatible
switch.
After connecting power supply it takes about 30 seconds to start camera. Then You can proceed to
connect to the camera via web browser.
The recommended way to start an IP camera and perform its configuration is a connection directly
to the network switch which is not connected to other devices. To obtain further information about
network configuration parameters (IP address, gateway, network mask, etc.) please contact your
network administrator.
Connection utilising network switch with PoE support
Connection utilising external power supply and network switch
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Data transmission
Network Switch
Computer
Data transmission
Power supply and
data transmission
Computer
IP Camera
Network Switch PoE
Data transmission
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
12
Connection utilising external power supply directly to the computer
Information:
Power supply adapter is not included. Please use power adapter with parameters specified in user s
manual.
CAUTION:
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
2.6. Initial configuration via the web browser
The default network settings for NVIP-2VE-6402M camera are :
1. IP address= 192.168.1.200
2. Network mask - 255.255.255.0
3. Gateway - 192.168.1.1
4. User name - root
5. Password - pass
Knowing the cameras IP address you need to appropriately set PC IP address, so the two devices can
operate in one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera ranges from
192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for
camera and PC computer
You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera
yourself or select DHCP mode (DHCP server is required in this method in target network) by using
web browser or by NMS software. When you use DHCP server check IP address lease and its linking
with camera MAC address to avoid changing or losing IP address during device operation or network/
DHCP server breakdown. You have to remember to use a new camera IP address after changing
network parameters.
After network setting configuration has been done, the camera can be connected to a target network.
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission - cross over cable
Computer
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
13
2.7. Security recommendations for network architecture and configuration
WARNING!
Below are shown security recommendations for network architecture and configuration
of CCTV systems that are connected to the Internet to reduce the risk
of unauthorized interference with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility) of
all applied network devices (recorders, cameras, routers, network switches, etc.) to the
severely complexity password. Use lowercase and uppercase letters, numbers, and special characters
if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices at
the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the
access to recorder system from the Internet on all ports, which gives possibility for an unauthorized
interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models of recorders,
cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has a UPnP feature and it is not used, turn it off.
7. If used network devices has a P2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
10. If used recorder has two network interfaces it is recommended to use both of them to physically
separate network for cameras and network for Internet connection. The only device in the system,
accessible from Internet will be recorder - there will be no physically access directly to any camera.
START-UP AND INITIAL CAMERA CONFIGURATION
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
14
3. NETWORK CONNECTION USING WEB BROWSER
3.1. Recommended PC specification for web browser connections
Requirements below apply to connection with an IP camera, assuming smooth image display in
1920 x 1080 resolution and 30 fps speed.
1. CPU Intel Core i5 3GHz or newer
2. RAM Memory min. 8 GB
3. VGA card (displaying Nvidia GeForce 1GB Ram or equivalent )
4. OS Windows 7/8/8.1/10
5. Network card 100/1000 Mb/s
3.2. Connection with IP camera via web browser
You have to enter camera IP address in the address bar. When you connect to the camera, web browser
will download the applet for displaying images from the camera. In Internet Explorer it may be
necessary to accept an ActiveX control. To do this, click the right mouse button on the message, select
"Install Active X control" and then click Install. After successfully NetIPCamera plug in downloading
run and install it on a computer.
NETWORK CONNECTION USING WEB BROWSER
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
15
If the installation fails, changing security settings for the IE browser is required. In order to do that,
please choose: Tools > Internet options > Security tab > Custom level and:
Under Download unsigned ActiveX controls - select either Enable or Prompt
Under Initialize and script ActiveX controls not marked as safe - select Enable or Prompt
You can also add the cameras IP address to trusted zone and set lowest security level for it.
In addition, when working in Windows Vista/7 the ActiveX applet may be blocked by Windows
Defender or User account control. In such case you should allow to run this applet, or simply disable
these functions.
After successful installation login window will be displayed. Default user is root and default password
is pass. For safety reasons, it is recommended to change default user name and password.
NETWORK CONNECTION UTILIZING WEB BROWSER
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
16
4. USING AND CONFIGURING
4.1 The Remote Preview Interface
1. View settings
Original size Automatic Size
Fill screen Full Screen
2. Camera functions
Live View On/Off Snapshoot Zoom In/out (digital)
On/Off Sound Record Video
PTZ panel
3. Live view alarms
Motion detection Color change Clarity change Scene change
4. Camera buffer
There is three possible options of view: REAL-TIME, BALANCED, FLUENT
WWW INTERFACE - USING AND CONFIGURING
1
2
3
4
Focus, Zoom settings
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
17
ELECTRIC CONNECTORS AND ACCESORIES
4.2 Lens control - Focus and Zoom Settings
The interface has a built-in side panel that allows remote control of zoom and focus.
5. CONNECTING ACCESORIES
5.1. Connecting audio input
Camera audio input allows to connect active microphone (with individual power supply).
zoom out
zoom in
focus -
focus +
one key
focus
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
18
ELECTRIC CONNECTORS AND ACCESORIES
6. RESTORING FACTORY DEFAULTS
NOVUS IP cameras allow to restore defaults via:
software (web browser level)
software (NMSiptool level)
6.1. Restoring factory defaults by software (web browser level)
User can restore default settings of the IP camera. To restore to default settings go to: Advanced
Config -> Config Backup & Restoretab. Process of restoring takes about two minutes.
6.2. Restoring factory defaults by software (NMSiptool level)
NMSip (version 1.23.4 or later) allows to restore factory defaults. To restore settings find camera via
NMSiptool, click right mouse button and choose Restore default configuration”. Next, within 30
seconds, it is required to turn the camera power off and on.
NVIP-2VE-6402M - Users manual (short form) ver 1.0
All rights reserved © AAT Holding S.A.
19
NOTES
2019-06-03 MO
AAT Holding S.A., ul. Puławska 431, 02-801 Warszawa, Polska
tel.: 22 546 07 00, faks: 22 546 07 59
www.novuscctv.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Novus NVIP-2VE-6402M (NVIP-2DN3034AV/IR-1P) Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi