Planet IGS-10020HPT/IGS-10020HPT-U Skrócona instrukcja obsługi

Kategoria
Sieć
Typ
Skrócona instrukcja obsługi
L2+ Industrial 8-/16-Port 802.3af/at PoE
Managed Switch
IGS-10020PT/IGS-10020HPT/IGS-20160HPT
Quick Installation Guide
Table of Contents
1. Package Contents ....................................................................................... 3
2. Requirements ............................................................................................. 4
3. Wiring the Power Inputs .............................................................................. 5
3.1 Grounding the Device .......................................................................... 7
4. Terminal Setup ........................................................................................... 8
4.1 Logging on to the Console.................................................................... 9
4.2 ConguringIPAddress ........................................................................10
5. Starting Web Management .........................................................................13
5.1 Logging in to the Industrial Managed PoE+ Switch ................................13
5.2. SavingConguration ........................................................................... 17
6. RecoveringBacktoDefaultConguration .....................................................19
7. Customer Support .....................................................................................20
3
1. Package Contents
Thank you for purchasing PLANET L2+ Industrial Managed Gigabit PoE+ Switch.
The descriptions of these models are as follows:
Model RJ45 Ports PoE+ Ports SFP Ports
IGS-10020PT 882
IGS-10020HPT 882
IGS-20160HPT 18 16 2
“Industrial Managed PoE+ Switch” mentioned in this Quick Installation Guide
refers to the above models.
Open the box of the Industrial Managed PoE+ Switch and carefully unpack it. The
box should contain the following items for each of the three models:
Item IGS-10020PT IGS-10020HPT IGS-20160HPT
Quick Installation Guide  
DIN-railKit  
WallMountingKit  
DB9 to RJ45 Interface
RS232 Console Cable  
RJ45 Dust Cap 9 9 19
SFP Dust Cap 2 2 2
If any item is found missing or damaged, please contact your local reseller for
replacement.
4
2. Requirements
zWorkstations running Windows XP/2003/2008/2012/Vista/7/8/10, MAC OS X or
later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPprotocols.
zSerial Port Connection (Terminal)
The above Workstations come with COM Port (DB9) or USB-to-RS232
converter.
The above Workstations have been installed with terminal emulator, such as
Hyper Terminal included in Windows XP/2003, putty or tera term.
Serial cable -- one end is attached to the RS232 serial port, while the other
end to the RJ45 console port of the Industrial Managed PoE+ Switch.
zEthernet Port Connection
 WorkstationsareinstalledwithEthernetNIC(NetworkInterfaceCard).
 Networkcables--Usestandardnetwork(UTP)cableswithRJ45connectors.
The above PC is installed with Web browser.
Note
It is recommended to use Internet Explorer 8.0 or above to access
the Industrial Managed PoE+ Switch. If the Web interface of the
Industrial Managed PoE+ Switch is not accessible, please turn off
the anti-virus software or firewall and then try it again.
5
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed PoE+ Switch indicates a DC inlet power
socket and consists of one terminal block connector within 6 contacts. Please follow
the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
zIGS-10020PT: 48V~56V DC
PWR1 PWR2
Fault
DI1 DO0 DO1DI0 GNDGND
Max. fault loading: 24V, 1A
DC Input:
48-56V , 6A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-1: IGS-10020PT Upper Panel
zIGS-10020HPT: 12~48V DC
PWR1 PWR2
Fault
DI1 DO0 DO1DI0 GNDGND
Max. fault loading: 24V, 1A
DC Input:
12-48V , 7A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-2: IGS-10020HPT Upper Panel
6
zIGS-20160HPT: 48-56V DC
DI
0DI
1DO
0DO
1GND GND
Fault
V1+ V2+
DC2DC1
Dual power input is required
for maximum PoE loading.
Refer to user’s manual for
more details.
Input: 48-56V , 7.5A max.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-3: IGS-20160HPT Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosening.
123456
V1+ V1- V2+ V2-
Power 1
(DC1) Power 2
(DC2)
Model Positive (+) Pin Negative(-)Pin
IGS-10020PT/IGS-10020HPT/
IGS-20160HPT Pin 1 / 5 Pin 2 / 6
Note
The wire gauge for the terminal block should be in the range from
12 to 24AWG.
7
3.1 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
PWR1 PWR2
Fault
DI1 DO0 DO1DI0 GNDGND
Max. fault loading: 24V, 1A
DC Input:
12-48V , 7A max.
1 2 3 4 5 6
1 2 3 4 5 6
Earth Ground
Note
EMD(Lightning)DAMAGEISNOTCONVEREDUNDERWARRANTY.
8
4. Terminal Setup
To congure the system, connect a serial cable to a COM port on a PC or
notebook computer and to RJ45 type serial (console) port of the Industrial
Managed PoE+ Switch. The console port of the Industrial Managed PoE+ Switch is
DCE already, so that you can connect the console port directly through PC without
the need of null modem.
PC/Workstation
with
Terminal emulation software
RJ45 to DB9 RS232 Cable
Serial Port
IP Address:
192.168.0.100
IGS Industrial Managed Switch
Figure 4-1: Industrial Managed PoE+ Switch Console Connectivity
A terminal program is required to make the software connected to the Industrial
Managed PoE+ Switch. Windows' Hyper Terminal program may be a good choice.
The Hyper Terminal can be accessed from the Start menu.
1. Click START, then Programs, Accessories and then Hyper Terminal.
2. When the following screen appears, make sure that the COM port should be
conguredas:
Baud: 115200
Parity:None
Data Bits: 8
Stop Bits: 1
FlowControl:None 
Figure 4-2: COM Port Conguration
9
4.1 Logging on to the Console
Once the terminal has been connected to the device, power on the Industrial
Managed PoE+ Switch and the terminal will display “running testing procedures”.
Note
The following console screen is based on the IGS-10020HPT. The
display of the IGS-10020PT and IGS-20160HPT is the same as that
of the IGS-10020HPT.
Then, the following message asks to log in user name and password as shown
in Figure 4-3. Please enter the factory default user name “admin" and password
“admin”.
UserName:admin
Password: admin
Figure 4-3: Console Login Screen
Note
1. For security reason, please change and memorize the new
password after this first setup.
2. Only accept command in lowercase letter under console inter-
face.
10
4.2 ConguringIPAddress
The Industrial Managed PoE+ Switch is shipped with default IP address shown
below:
IPAddress:192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Industrial
Managed PoE+ Switch, please use the procedure as follows:
Display of the current IP Address
1.Atthe“#” prompt, enter “show ip interface brief”.
2. The screen displays the current IP address shown in Figure 4-4.
Figure 4-4: IP Information Screen
11
CongurationoftheIPAddress
3.At the “#” prompt, enter the following command and press <Enter> as shown
in Figure 4-5.
The previous command would apply the following settings for the Industrial
Managed PoE+ Switch.
IPAddress:192.168.1.100
Subnet Mask: 255.255.255.0
Figure 4-5: Conguring IP Address Screen
4. Repeat step 1 to check if the IP address has changed.
12
Storethecurrentswitchconguration
5.Atthe“#” prompt, enter the following command and press <Enter>.
#copyrunning-congstartup-cong
Figure 4-6: Saving Current Conguration Command Screen
If the IP is successfully congured, the Industrial Managed PoE+ Switch will apply
the new IP address setting immediately. You can access the Web interface of the
Industrial Managed PoE+ Switch through the new IP address.
Note
If you are not familiar with the console command or the related
parameter, enter “help” anytime in console to get the help
description.
13
5. Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed PoE+ Switch. Note the Industrial Managed PoE+ Switch is congured
through an Ethernet connection. Please make sure the manager PC must be set to
the same IP subnet address.
For example, the default IP address of the Industrial Managed PoE+ Switch is
192.168.0.100, then the manager PC should be set to 192.168.0.x (where x
is a number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
IP Address: 192.168.0.x
IP Address: 192.168.0.100
IGS Industrial Switch
RJ45/UTP-Cable
Figure 5-1: IP Management Diagram
5.1 Logging in to the Industrial Managed PoE+ Switch
1. Use Internet Explorer 8.0 or above for Web browser and enter IP address
http://192.168.0.100 (the factory-default IP address) to access the Web
interface.
2. When the following dialog box appears, please enter the default user name
“admin” and password “admin” (or the password you have changed before) as
shown in Figure 5-2.
DefaultIPAddress:192.168.0.100
DefaultUserName:admin
Default Password: admin
Figure 5-2: Web Login Screen
14
Note
The following web screen based on IGS-10020HPT will be the same
as that of IGS-10020PT/IGS-20160HPT.
3.Afterenteringthepassword,themainscreenappearsasshowninFigure5-3.
Figure 5-3: Web Main Screen of Industrial Managed PoE+ Switch
The Switch Menu on the top of the Web page lets you access all the commands
and statistics the Industrial Managed PoE+ Switch provides. The Switch Menu
always contains one or more buttons, such as “System”, “Switching”, “QoS”,
“Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Figure 5-4: Switch Menu
Figure 5-5: Switch Menu -- System
15
Figure 5-6: Switch Menu – Switching
Figure 5-7: Switch Menu -- QoS
Figure 5-8: Switch Menu -- Maintenance
16
Figure 5-9: Switch Menu -- Security
Figure 5-10: Switch Menu -- PoE
Figure 5-11: Switch Menu – Ring
17
Figure 5-12: Switch Menu – ONVIF
Note
If you are not familiar with Switch functions or the related param-
eter, press “Help icon” anytime on the Web page to get the help
description.
Now, you can use the Web management interface to continue the Switch
management or manage the Switch by console interface.
Please refer to the user’s manual for more.
5.2.SavingConguration
To save all applied changes and set the current conguration as a startup
conguration on the Web user interface, the startup-conguration le will be
loaded automatically across a system reboot.
1. Click the Save icon on the top Switch Menu bar.
Figure 5-13: Save Cong -- Hot Key
2. Press the “SaveConguration” button.
18
3. Or the other way to save the setting is to Click Maintenance, Save Startup
Cong.
Figure 5-14: Save Cong -- Maintenance
19
6.RecoveringBacktoDefaultConguration
To reset the IP address to the default IP address “192.168.0.100” and the
user password to factory default mode (default password is admin), press the
hardware-based reset button on the front panel for about 10 seconds. After the
device is rebooted, you can log in the management Web interface within the
same subnet of 192.168.0.xx and default password. Be noted that all the previous
setups will be disappeared after the factory default reset is made.
P1 P2
Ring R.O.
Fault
910
100/1G/2.5G SFP
10/100/1000T
IGS-10020HPT
6
4
2
7
5
3
1
Reset
8
9
LNK/ACT1G/2.5G LNK/ACT1G/2.5G
10 LNK
ACT
LNK
ACT
PoE-in-Use
Console
115200,N,8,1
802.3at PoE+
Reset Button
Figure 6-1: IGS-10020PT/IGS-10020HPT Reset Button
1
3
5
7
2
4
6
8
9
11
13
15
10
12
14
16
Reset
Console
115200,N,8,1
19
20
17
18
P1 P2
Ring R.O.
Fault
IGS-20160HPT
ACTLNK
PoE-in-Use
802.3at PoE+
ACT1000 LNK
ACT10/100 LNK
Reset Button
Figure 6-2: IGS-20160HPT Reset Button
20
7. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resourceon PLANET website rsttocheck ifitcould solveyour issue.If youneed
moresupportinformation,pleasecontactPLANETswitchsupportteam.
PLANETonlineFAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
IGS-10020PT/IGS-10020HPT/IGS-20160HPT User’s Manual:
https://www.planet.com.tw/en/support/downloads?method=keyword&keyword=IGS
&view=3&page=1#list
(Please select your switch model name from the Product Model drop-down menu.)
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Planet IGS-10020HPT/IGS-10020HPT-U Skrócona instrukcja obsługi

Kategoria
Sieć
Typ
Skrócona instrukcja obsługi