Elk Home 57027/4 Instrukcja instalacji

Typ
Instrukcja instalacji
-1- elkhome.com
ITEM#: 57027/4
WARNING: DISCONNECT POWER AT THE MAIN
FUSE BOX BEFORE INSTALLATION.
WARNING:
This xture is intended for installation in
accordance with the National Electrical Code
(NEC) and all local code specications. If you are
not familiar with code requirements, installation
by a certied electrician is recommended.
Before assembly, remove all parts and part
packages from box. If anything is missing, please
contact the retailer from which the product was
purchased.
A
BB
W
JUNCTION
BOX
V
GROUND
SCREW
1. Carefully pull house wires down out of junction
box so house wires are easily accessed to
connect xture wires.
2. If screw collar loop (W) is already attached to
mounting bracket (A), proceed to Step 3. To
assemble screw collar loop (W) to mounting
bracket (A): Hold mounting bracket (A) so head
of ground screw is pointing down towards oor.
Hold threaded pipe so two hexnuts already
attached to threaded pipe (E) are pointing down
towards oor. From side of mounting bracket
with ground screw head, screw short end of
threaded pipe (E) into hole in center of mounting
bracket (A) until hexnut on threaded pipe (E)
touches mounting bracket. Thread hexnut (V)
onto end of threaded pipe (E). Tighten hexnut
(V) to secure threaded pipe (E) to mounting
bracket (A). Thread screw collar loop (W) onto
end of threaded pipe pointing down towards
oor. Tighten screw collar loop up against
hexnut on threaded pipe (E).
3. Place mounting bracket (A) up against junction
box. Screw collar loop (E) should be pointing
down towards oor. Align each slot in mounting
bracket (A) with each hole in junction box.
4. Thread one junction box screw (B) into each
slot in mounting bracket (A) and into holes in
junction box. Tighten junction box screws (B) to
secure mounting bracket (A) to junction box.
CAUTION: Make sure house wires are still easily
accessible.
DO NOT pinch wires between mounting bracket
and ceiling.
E
ANY QUESTIONS CALL: 800-613-3261
M-F 8:00AM-6:00PM ET
-2- elkhome.com
ITEM#: 57027/4
5. Lower shade (K) over xture body (O).
6. Screw hub (G) onto top of center stem (M).
7. Carefully push xture wires from top of xture
body (O) up through bottom of center stem (M).
Pull xture wires out of top of hub (G) on top of
center stem (M). Pull xture wires taut. Screw
bottom of center stem (M) onto top of xture
body (O).
8. Push xture wires up through bottom of loop
(P). Pull xture wires taut. Screw bottom of loop
(P) onto threaded pipe protruding from top of
hub (G).
9. Lower one glass shade (R) down over each
socket. Slip socket cover (T) over each socket.
10. Thread socket ring (X) onto each socket. Tighten
socket rings (X) to secure glass shades (R) in
place. DO NOT over tighten.
11. Screw recommended bulbs (E26 Edison bulb
type, not included) into sockets. Verify correct
bulb wattage marked on socket of xture.
WARNING: DO NOT exceed maximum bulb
wattage.
12. Hold one arm (L) so threaded end of arm (L) is at
the bottom. Slip threaded end of arm (L) through
one bracket on inside of shade (K). Screw
threaded cap (N) onto threaded end of arm (L).
DO NOT tighten threaded cap (N). This will be
done after all arms (L) are assembled.
13. Slip hook at top of arm (L) through one small
loop on side of hub (G).
14. Repeat steps 12 and 13 to assemble remaining
arms (L) to xture.
15. After all arms (L) have been attached, completely
tighten all threaded caps (N).
16. Determine desired hanging height of xture. Cut
chain (H) to length to achieve desired.
17. Slip chain link at end of chain (H) onto loop (P).
18. Weave xture wires through chain links,
skipping every other chain link.
19. Slip threaded ring (F) down over end of chain (H)
with xture wires.
20. Position canopy (D) so outside of canopy is
pointing down towards xture. Slip hole in
canopy (D) over end of chain (H).
F
D
M
O
K
G
L
N
P
H
BULB
X
T
R
-3- elkhome.com
ITEM#: 57027/4
25. Twist end of house lead wire (black) and end
of xture lead wire together. Twist wire nut (C)
onto ends of wires. Completely tighten wire nut
(C). Twist end of house neutral wire (white) and
end of xture neutral wire together. Twist wire
nut (C) onto ends of wires. Completely tighten
wire nut (C). Reference chart to the right for
correct wire connections.
26. Wrap electrical tape (not included) around wire
nuts (C) and wires. Ensure wires are securely
fastened into wire nuts.
27. Carefully push all wires and wire nuts into
junction box.
FIXTURE LEAD WIRE HOUSE LEAD WIRE
(BLACK)
FIXTURE GROUND
WIRE
HOUSE GROUND
WIRE (COPPER)
FIXTURE NEUTRAL
WIRE HOUSE NEUTRAL WIRE
(WHITE)
C
Connect Black Lead
Supply (House) Wire to:
Connect White Neutral
Supply (House) Wire to:
Black Wire or,
*Parallel Cord
(Round and Smooth) or,
Insulated Wire
(other than green)
with Copper Conductor.
White Wire or,
*Parallel Cord
(Square and Ridged) or,
Insulated Wire
(other than green)
with Silver Conductor.
*When parallel wire (SPT 1 & SPT 2) is used:
The lead wire is round in shape or smooth.
The neutral wire is square in shape or ridged.
No printed words on
wire insulation or,
Printed words on
wire insulation or,
21. Strip 3/4” of insulation from ends of xture
wires.
22. Raise xture up to ceiling. Attach link at end of
chain (H) to screw collar loop (W).
23. Carefully push xture wires up through hole
in screw collar loop (W) attached to mounting
bracket (A) and out end of threaded pipe inside
junction box. Carefully pull xture wires so they
are easily accessible to connect to house wires.
24. Slightly loosen ground screw on mounting
bracket (A). Do not completely remove ground
screw. Wrap house ground wire (copper) around
ground screw, leaving enough ground wire
to attach to xture ground wire. Twist end of
xture ground wire and end of house ground
wire together. Twist wire nut (C) onto ends of
wires. Completely tighten wire nut (C). Reference
chart below for correct wire connections.
Connect Supply (House) Ground Copper Wire to:
Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.
W
JUNCTION BOX
GROUND
SCREW
HOUSE
GROUND
WIRE
(COPPER)
FIXTURE
GROUND WIRE
C
A
H
-4- elkhome.com
ITEM#: 57027/4
28. Raise canopy (D) up to ceiling. Pass hole in
canopy (D) over screw collar loop (W). Position
canopy (D) up against ceiling.
29. Raise threaded ring (F) up to canopy (D). Screw
threaded ring (F) onto screw collar loop (W).
Tighten threaded ring (F) to secure xture to
ceiling.
D
W
F
F
W
D
H
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Elk Home 57027/4 Instrukcja instalacji

Typ
Instrukcja instalacji

w innych językach